About

  • High quality, heavy-duty liquid filled gauge
  • Vacuum and compound ranges through 0 psi to 15,000 psi
  • Die cast Brass case with natural Brass finish
  • Copper alloy or 316 Stainless Steel and Brass wetted parts
  • Cleaning for Oxygen Service (O2) is available only for dry or HL (Halocarbon) filled gauges
  • For gauges with MIP, GY40 fill is standard for liquid filled gauges

Featured Specifications

Accuracy

±1.6% Full Scale

Gauge Size

2-1/2 in

Pressure Range

0 to 15,000 psi

Connection

1/4" NPT

Connection Location

Bottom

Product Specifications

Type
Pressure Gauge
Cover Ring Material
Polished Brass
Accuracy
±1.6% Full Scale
Connection
1/4" NPT
Connection Location
Bottom
Lens/Display Material
Acrylic with O-Ring Seal
Gauge Size
2-1/2 in
Dial
Aluminum, white background with black scale. UV resistant.
Case Type
Brass, Bottom Connection
Pressure Range
0 to 15,000 psi
Scale Option
psi Single Scale
Case Material
Die Cast Brass (Natural Brass Finish) with Safety Relief Plug
Measuring Element
316 Stainless Steel Coiled Safety Tube
Series
300
Pointer
Balanced Aluminum, Black Finish
Movement
Brass and Nickel-Silver with Highly Polished Bearing Surfaces
Fill Liquid
Glycerin
Warranty
3 yr

Temperature Ranges

Media Temperature Range ºF
-4 to 140 ºF
Media Temperature Range ºC
-20 to 60 ºC
Ambient Temperature Range ºF
0 to 160 ºF
Ambient Temperature Range ºC
-18 to 71 ºC
Optional Temperature Range ºF
-40 to 212 ºF
Optional Temperature Range ºC
-40 to 100 ºC

Working Pressure Limitations

Working Pressure Limitations
Dynamic Pressure
The working pressure should be limited to 60% of the dial range

Static Pressure
The working pressure, where no sharp fluctuations occur, should be limited to 90% of the dial range

Options and Accessories

Installed Options and Accessories
Available
  • Maximum Indicating Pointer (MIP)
  • Glass Lens Overlay (GLO)
  • Safety Glass Overlay (SGO)
  • Chrome Front Flange (CFF)
  • Chrome Front Flange w/o Holes (CFFN)
  • Brass Front Flange (BFF)
  • Rear Flange (RF)
  • Chrome Cover Ring (CCR)
  • Increased Accuracy from 1.5% to 1.0% (IA)
  • SAE J1926-3:7/16-20 Adjustable Connection (SST) Includes FKM O-ring. Consult factory for availability.
  • 10-32-UNF-2B (10-32)
  • Orifice - Brass Threaded 0.3mm (BT3)
  • Orifice - Brass Threaded 0.4mm (BT4)
  • Orifice - Brass Threaded 0.8mm (BT8) - Standard
  • Rubber Case Protectors (RCP)
  • Laser Marking (LM)
  • Stainless Steel Tagging (ST)
Gauge Fill Options
  • Silicone (SL)
  • Halocarbon (HL)
  • -40 Degree Service (GY40)
  • Mineral Oil (MO)
Certificates
  • Certified Calibration (CC)
  • Cleaning for Oxygen Service (O2), Up to 1000 psi
  • Cleaning for Oxygen Service (O2), 1500 psi and up
Uninstalled Options and Accessories
  • Chrome Adaptor Ring (25-13-1-CHROME-AR)
  • Rubber Case Protector (25-123459-0-RCP)
  • Certificate of Cleaning (COCL)
  • Certificate of Conformance (COC)
Assembly Options
NOSHOK offers multiple assembly options to meet your specific system requirements. Consult factory to discuss your customized solution.
Diaphragm Seals
NOSHOK offers a wide variety of standard & elevated pressure, and reduced pressure replaceable and non-replaceable diaphragm seals, designed to isolate and/or protect the pressure measuring instrument from corrosive, viscous, contaminated or very high temperature process media.
Distribution Manifolds
NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths.
Metric Dials and Customized Special Dials
  • Dual scale metric dials in psi/bar, psi/kPa and psi/kg/cm2
  • Other scales are available for specific sizes and ranges, such as single scale bar and kPa, refrigerant scales and altitude scales
  • Customized special dials such as non-standard metric scale, tons of ram, lbs. of force, etc. are available in small quantities (as few as one piece) on some NOSHOK gauges
Please consult the factory for availability.
Pressure Snubbers Piston Type
  • Resist clogging and are self-cleaning
  • Five different sized pistons included with each snubber to ensure the correct amount of snubbing for virtually every application
  • Available in Brass and 316 Stainless Steel in 1/4" NPT, 1/2" NPT or SAE J1926-3: 7/16-20
  • Weight approximately 0.2 lb. for 1/4" & 7/16", and approximately 0.4 lb. for 1/2"​​​​​​
Pressure Snubbers Sintered Type
  • Cost effective solution to protect expensive instrumentation
  • Increases gauge readability by smoothing out pressure surges, pulsations and spikes
  • 5 basic elements available for each snubber to accommodate specific application needs
  • Snubbing action achieved by utilizing a corrosion resistant 316 Stainless Steel sintered porous element
  • Exotic materials or intermediate disc grades available
  • Provides long service life with no moving parts to wear out
  • Weight approximately 0.2 lb. for 1/4" & 7/16", and approximately 0.4 lb. for 1/2
Refrigeration Gauges with Dials Reading in Pressure and Temperature
Refrigeration gauges with dials reading in pressure and temperature are available in NOSHOK 300, 400 and 500 Series Pressure Gauges for R-12 and R-22
Steam Syphons
  • Protect the instrument from the damaging effects of high temperature steam
  • Recommended for use in all steam applications
  • Available in 1/4" and 1/2" NPT sizes in welded steel, welded 316 Stainless Steel or seamless 316 Stainless Steel with ratings to 3800 psi at 850 ºF
Swivel Adapters
  • Temperature ratings: 15,000 psi at 200 ºF and 3000 psi at 1000 ºF
  • Used with gauges and gauge valves to adjust the line of sight
  • Rotates 360º to allow the connected instrument to be positioned in the desired direction
  • The pressure connection is achieved with a tapered cone style compression fitting simply by tightening the swivel hex nut
  • All 316 Stainless Steel construction
  • Standard with 1/2" NPT male process - 1/2" NPT female instrument connections
  • Also available with 1/4" NPT connections, same specifications apply
  • Weight approximately 0.8 lb.

Warnings

Warnings
Glycerin or silicone could result in a spontaneous chemical reaction or explosion when combined with strong oxidizing agents including, but not limited to, chlorine, oxygen, hydrochloric or nitric acid, and hydrogen peroxide. Do not use glycerin or silicone filled gauges or accessories in these types of service. Consult factory for application assistance.

This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.

Note

Note
Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.

Applications

Application
  • Automotive
  • Construction
  • Hydraulics & pneumatics
  • Mining
  • Stamping & forming presses
  • Transportation

Limitations Which Apply Are

Limitations Which Apply Are
  • Bourdon tube pressure gauges must be used within their calibrated maximum range to prevent damage
  • The pressure gauges must be operated within the following working pressure limits:
    • Dynamic Pressure application, 60% of the dial range
    • Static Pressure applications, where no sharp fluctuations occur, 90% of the dial range
  • The gauges must be operated within specified ambient temperature ranges
  • Determination of gauge failures will be made by NOSHOK, Inc., which will use its equipment and personnel or a certified test facility specializing in this type of evaluation and determination. Gauge failures determined to be caused by over-range, incompatibility with environment or product media and abuse will not be considered under this warranty. NOSHOK, Inc. will, at its discretion, repair or replace the working parts of the damaged gauge without cost to the customer. This written warranty applies only to the NOSHOK gauges referenced in the first paragraph of this warranty, sold by NOSHOK, Inc. and its authorized distributors.

Caution

Caution
Operating conditions including, but not limited to, system pressure, media compatibility and ambient conditions must be considered when selecting gauges and accessories. Improper selections and use of gauges could possibly cause gauge failure and lead to possible property damage or personal injury. Refer to the American National Standard ANSI B40.1 for the correct selection and use of gauges. A copy of this standard may be obtained from the American Society of Mechanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017.

In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.

Prop 65 Warnings

Prop 65 Warnings
⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov