About
- Current and voltage outputs available
- 316 stainless Steel and Elgiloy wetted parts
- Factory Mutual and Canadian Standards Association approved
- Built to suppress RFI, EMI, and ESD
- NACE MR0175/ISO 15156 compliant
- NSI/ISA-12.27.01 approved single seal
Featured Specifications
Accuracy
0.25%
Pressure Range
0 to 100 psig
Output Signal
4 mA to 20 mA, 2-wire
Process Connection
1/4 in
Electrical Connection
1/2" NPT Male Conduit with 6 ft Integral Cable
Assets
Product Specifications|Additional Information|Options and Accessories|Load Limitations|Applications|Limitations Which Apply Are|Prop 65 Warnings
Product Specifications
▲| Product Series | 623 |
| Process Connection | 1/4" NPT Male |
| Approximate Weight | 12 oz |
| Housing Material | 316 Stainless Steel |
| Output Signal | 4 mA to 20 mA, 2-wire |
| Electrical Connection | 1/2" NPT Male Conduit with 6 ft Integral Cable |
| Power Requirement | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
| Pressure Range | 0 to 100 psig |
| Absolute Pressure Range | 0 to 100 psia |
| Accuracy | 0.25% |
| Stability | ≤ ±0.2% full scale for 1 year, non-accumulating |
| Response Time | ≤1 ms |
| Service Life | > 100,000,000 Load Cycles |
| Compensated Temperature Range ºF | 32 to 176 ºF |
| Compensated Temperature Range ºC | 0 to 80 ºC |
| Note for Compensated Temperature Range | Zero effect is ±0.011% full scale/ºF within compensated range Span effect is ±0.011% full scale/ºF within compensated range |
| Media Temperature Range ºF | -40 to 212 ºF |
| Media Temperature Range ºC | -40 to 100 ºC |
| Ambient Temperature Range ºF | -22 to 176 ºF |
| Ambient Temperature Range ºC | -30 to 80 ºC |
| Measuring Element | 623 Series is 316 Stainless Steel for ranges up through 0 psi to 300 psi, 316 Stainless Steel and Elgiloy for ranges 0 psig to 500 psig and higher |
| Connection Material | 316 Stainless Steel |
| Environmental Rating | Ingress Protection (IP65) to Ingress Protection (IP67) dependent upon electrical connection |
| Electrical Protection | Reverse polarity, over-voltage and short circuit protected |
| Electromagnetic Rating | European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
| Shock According to International Electrotechnical Commission (IEC) 60068-2-27 | 1,000 g |
| Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 | 20 g |
| Warranty | 3 yr |
Additional Information
▲| Additional Information | NOSHOK 623 and 624 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as follows:
|
Options and Accessories
▲| Options and Accessories |
|
| Assembly Options | NOSHOK offers multiple assembly options to meet your specific system requirements. Consult factory to discuss your customized solution. |
| Digital Indicators | NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. |
| Pressure Snubbers - Piston Type |
|
| Pressure Snubbers - Sintered Type |
|
| Steam Syphons |
|
| Swivel Adapters |
|
Load Limitations
▲| Current for 4 to 20 Milliampere (mA)_A | 0.02 A |
| Resistance for 1 to 5 Direct Current (DC) Voltage, 3-Wire | ≥ 10,000 O |
Applications
▲| Applications |
|
Applications
▲| Application |
|
Limitations Which Apply Are
▲| Limitations Which Apply Are | These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Prop 65 Warnings
▲| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |