About
- Corrosion-resistant fillable dry or liquid-filled gauge
- Vacuum and compound ranges through 0 psi to 20,000 psi
- 316 Stainless Steel wetted parts
- Cleaning for Oxygen Service (O2) is available only for dry or HL (Halocarbon) filled gauges
- For gauges with MIP, GY40 fill is standard for liquid filled gauges
Featured Specifications
Accuracy
±1.6% Full Scale
Gauge Size
2-1/2 in
Pressure Range
0 to 5,000 psi
Connection
1/4" NPT
Connection Location
Back
Documents
Product Specifications|Temperature Ranges|Working Pressure Limitations|Options and Accessories|Note|Applications|Limitations Which Apply Are|Caution|Prop 65 Warnings
Product Specifications
▲| Type | Pressure Gauge |
| Connection | 1/4" NPT |
| Connection Location | Back |
| Connection Material | Stainless Steel |
| Cover Ring Material | Polished 304 Stainless Steel |
| Accuracy | ±1.6% Full Scale |
| Lens/Display Material | Trogamide |
| Dial | Aluminum, White Background with Black Scale. Ultraviolet (UV) Resistant. |
| Gauge Size | 2-1/2 in |
| Case Type | Stainless Steel (SS) Case, Liquid Filled, Back Connection |
| Pressure Range | 0 to 5,000 psi |
| Scale Option | psi Single Scale |
| Case Material | Polished 304 Stainless Steel with Safety Relief Plug |
| Measuring Element | Coiled Safety Tube |
| Pointer | Balanced Aluminum, Black Finish |
| Movement | Stainless Steel with Highly Polished Bearing Surfaces |
| Warranty | 3 yr |
| Related Items |
|
Working Pressure Limitations
▲| Working Pressure Limitations | Dynamic Pressure The working pressure should be limited to 60% of the dial range. Static Pressure The working pressure, where no sharp fluctuations occur, should be limited to: <15,000 psi: 90% of the dial range, >15,000 psi: 75% of the dial range |
Options and Accessories
▲| Installed Options and Accessories | Available
|
| Uninstalled Options and Accessories |
|
| Ammonia Refrigeration Gauges | Ammonia and refrigeration gauges with dials reading in both pressure and temperature are available in 400/500 Series 2-1/2" and 4" sizes |
| Assembly Option for Indication, Output, and Isolation/Bleed | NOSHOK offers multiple assembly options to meet your specific system requirements. Consult factory to discuss your customized solution. For example, you can simplify your system with this easy-to-install solution from NOSHOK. Three simple components that require a single threaded connection in your piping system will provide local indication, analog output and block/isolate with bleed function. This product grouping is an ideal solution for a variety of applications including oil and gas, and is available in several high pressure ranges, including 5,000, 10,000 and 15,000 psi. Special design for Shale Gas applications. This example represents a general solution; however, we offer a diverse range of gauges, transmitters and valves which are available with a variety of connection options and ranges to suit your needs. (Photo shows 40-400 Series Pressure Gauge (Local Indication), 621 Series Pressure Transmitter (Control Output), and 200 Series Multi-Port Valve (Block/Isolate & Bleed). |
| Diaphragm Seals | NOSHOK offers a wide variety of standard & elevated pressure, and reduced pressure replaceable and non-replaceable diaphragm seals, designed to isolate and/or protect the pressure measuring instrument from corrosive, viscous, contaminated or very high temperature process media. |
| Distribution Manifolds | NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths. |
| Metric Dials and Customized Special Dials |
|
| Pressure Snubbers Piston Type |
|
| Pressure Snubbers Sintered Type |
|
| Refrigeration Gauges with Dials Reading in Pressure and Temperature | Refrigeration gauges with dials reading in pressure and temperature are available in NOSHOK 300, 400 and 500 Series Pressure Gauges for R-12 and R-22 |
| Steam Syphons |
|
| Swivel Adapters |
|
Applications
▲| Application |
|
Limitations Which Apply Are
▲| Limitations Which Apply Are |
|
Caution
▲| Caution | Operating conditions including, but not limited to, system pressure, media compatibility and ambient conditions must be considered when selecting gauges and accessories. Improper selections and use of gauges could possibly cause gauge failure and lead to possible property damage or personal injury. Refer to the American National Standard ANSI B40.1 for the correct selection and use of gauges. A copy of this standard may be obtained from the American Society of Mechanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Prop 65 Warnings
▲| Prop 65 Warnings | ⚠️ WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |